Asymptotic Effectiveness-NTU Formulas for Multipass Plate Heat Exchangers
S. Kandlikar, and R. Shah. Journal of Heat Transfer, 111 (2):
314-321(May 1989)
Abstract
The effectiveness of a plate heat exchanger with a finite number of plates is affected by the end channels, and the channels between two adjacent passes. These effects become less significant as the number of thermal plates becomes large, N > 40, as shown by Kandlikar and Shah (1989). In the present paper, closed-form equations are derived for plate heat exchangers with N = infinity in terms of temperature effectiveness Psub 1 as a function of the capacity rate ratio Rsub 1 and the number of transfer units NTUsub 1 for the following pass arrangements: 1-1, 2-1, 2-2, 3-1, 3-2, 3-3, 4-1, 4-2, 4-3, and 4-4.
%0 Journal Article
%1 kandlikar1989b
%A Kandlikar, S. G.
%A Shah, R. K.
%D 1989
%J Journal of Heat Transfer
%K heat-exchanger heat-transfer
%N 2
%P 314-321
%T Asymptotic Effectiveness-NTU Formulas for Multipass Plate Heat Exchangers
%V 111
%X The effectiveness of a plate heat exchanger with a finite number of plates is affected by the end channels, and the channels between two adjacent passes. These effects become less significant as the number of thermal plates becomes large, N > 40, as shown by Kandlikar and Shah (1989). In the present paper, closed-form equations are derived for plate heat exchangers with N = infinity in terms of temperature effectiveness Psub 1 as a function of the capacity rate ratio Rsub 1 and the number of transfer units NTUsub 1 for the following pass arrangements: 1-1, 2-1, 2-2, 3-1, 3-2, 3-3, 4-1, 4-2, 4-3, and 4-4.
@article{kandlikar1989b,
abstract = {The effectiveness of a plate heat exchanger with a finite number of plates is affected by the end channels, and the channels between two adjacent passes. These effects become less significant as the number of thermal plates becomes large, N > 40, as shown by Kandlikar and Shah (1989). In the present paper, closed-form equations are derived for plate heat exchangers with N = infinity in terms of temperature effectiveness Psub 1 as a function of the capacity rate ratio Rsub 1 and the number of transfer units NTUsub 1 for the following pass arrangements: 1-1, 2-1, 2-2, 3-1, 3-2, 3-3, 4-1, 4-2, 4-3, and 4-4.},
added-at = {2016-10-06T16:58:10.000+0200},
author = {Kandlikar, S. G. and Shah, R. K.},
biburl = {https://www.bibsonomy.org/bibtex/2a60f86f4f87ff799bfe25c5716b85997/jrdn},
interhash = {1a7d27f2ae9cda1c2a03e8cbfdb5d8e9},
intrahash = {a60f86f4f87ff799bfe25c5716b85997},
journal = {Journal of Heat Transfer},
keywords = {heat-exchanger heat-transfer},
month = may,
number = 2,
pages = {314-321},
timestamp = {2016-10-06T16:58:10.000+0200},
title = {Asymptotic Effectiveness-NTU Formulas for Multipass Plate Heat Exchangers },
volume = 111,
year = 1989
}