Conference,

Simulating integrated volt/var control and distributed demand response using GridSpice

, and .
(2011)cited By (since 1996) 0; Conference of 2011 IEEE 1st International Workshop on Smart Grid Modeling and Simulation, SGMS 2011; Conference Date: 17 October 2011 through 17 October 2011; Conference Code: 87803.
DOI: 10.1109/SGMS.2011.6089204

Abstract

This paper proposes VVCDDR, an integrated volt/var control scheme which also uses distributed demand response capacity on distribution networks to improve the reliability and efficiency of the distribution network. The paper uses a new simulation platform, GridSpice, to show that demand response resources can be used to maintain a flat and stable voltage profile over the feeder without increasing the allocation of voltage regulators and capacitor banks. The improved voltage profile allows for a safe reduction of voltage while ensuring that all loads remain within the standard acceptable voltage range. Previous studies have shown that a reduction of the load voltage translates into lower power consumption, a technique known as conservation voltage reduction (CVR). The simulation platform, GridSpice, built on top of Gridlab-D 11, is the first distribution simulator to consider volt/var control, demand response, and distribution automation in a single simulation. © 2011 IEEE.

Tags

Users

  • @adnasiak

Comments and Reviews