Experimental measurements of fouling resistance were carried out in a double-pipe heat exchanger (HE), with geothermal water flowing in the inner tube and tap water in the annular space. Tests were performed using waters from a geothermal well in central Serbia whose production temperature remained practically constant (52 °C) throughout the 90-day experiment. Analysis of the data showed that the change in fouling resistance was a linear function of time.
%0 Journal Article
%1 Milanovic2006
%A Milanovic, Predrag
%A Jacimovic, Branislav
%A Genic, Srbislav
%D 2006
%J Geothermics
%K scale 2006 heat-exchanger geothermal
%P 79-86
%R 10.1016/j.geothermics.2005.11.003
%T Experimental measurement of fouling resistance in the heat exchanger of a geothermal system
%U http://dx.doi.org/10.1016/j.geothermics.2005.11.003
%V 35
%X Experimental measurements of fouling resistance were carried out in a double-pipe heat exchanger (HE), with geothermal water flowing in the inner tube and tap water in the annular space. Tests were performed using waters from a geothermal well in central Serbia whose production temperature remained practically constant (52 °C) throughout the 90-day experiment. Analysis of the data showed that the change in fouling resistance was a linear function of time.
@article{Milanovic2006,
abstract = {Experimental measurements of fouling resistance were carried out in a double-pipe heat exchanger (HE), with geothermal water flowing in the inner tube and tap water in the annular space. Tests were performed using waters from a geothermal well in central Serbia whose production temperature remained practically constant (52 °C) throughout the 90-day experiment. Analysis of the data showed that the change in fouling resistance was a linear function of time.},
added-at = {2011-01-19T18:06:56.000+0100},
author = {Milanovic, Predrag and Jacimovic, Branislav and Genic, Srbislav},
biburl = {https://www.bibsonomy.org/bibtex/23e9b356409ab19b62d8d6fee4e816842/thorade},
doi = {10.1016/j.geothermics.2005.11.003},
file = {:\\dms11\\geotecpro\\GT_ENERG\\ClusterWissen\\Literatur\\Quellen\\Milanovic2006.pdf:PDF},
interhash = {b6c75f9108151706a37a25e0843172fb},
intrahash = {3e9b356409ab19b62d8d6fee4e816842},
journal = {Geothermics},
keywords = {scale 2006 heat-exchanger geothermal},
pages = {79-86},
timestamp = {2011-01-19T18:06:56.000+0100},
title = {Experimental measurement of fouling resistance in the heat exchanger of a geothermal system},
url = {http://dx.doi.org/10.1016/j.geothermics.2005.11.003},
volume = 35,
year = 2006
}