Analysis of Active Power Flow Control with Phase Shifting Transformer in AC Transmission Line
T. Zin. International Journal of Trend in Scientific Research and Development, 2 (6):
666-672(October 2018)
Abstract
Nowadays, active power flow should be controlled because voltage fluctuation occurred on various load conditions. Phase shifting transformer PST is used to control the active power flow in three phase electricity transmission network. It can increase reliability and can serve as an alternative to new investments in overhead lines. The control of active power flow is achieved by adjusting the phase angle of the voltages at the PST terminals. In this paper, 230 kV AC transmission line is chosen for active power flow control. Two conditions, maximum and minimum load conditions are considered as a case study for active power flow control performance in a selected line. Simulation of active power flow with PST model is carried out by using Matlab software. Finally, according to simulation results, system voltages and active power depend phase angles are revealed in this paper. Thandar Oo | Su Mon Myint | Aye Khaing Zin Änalysis of Active Power Flow Control with Phase Shifting Transformer in AC Transmission Line" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-6 , October 2018, URL: http://www.ijtsrd.com/papers/ijtsrd18593.pdf
%0 Journal Article
%1 noauthororeditor
%A Zin, Thandar Oo | Su Mon Myint | Aye Khaing
%D 2018
%J International Journal of Trend in Scientific Research and Development
%K Electrical Engineering active angle changer control flow line load on phase power shift shifting tap transformer transmission
%N 6
%P 666-672
%T Analysis of Active Power Flow Control with Phase Shifting Transformer in AC Transmission Line
%U http://www.ijtsrd.com/engineering/electrical-engineering/18593/analysis-of-active-power-flow-control-with-phase-shifting-transformer-in-ac-transmission-line/thandar-oo
%V 2
%X Nowadays, active power flow should be controlled because voltage fluctuation occurred on various load conditions. Phase shifting transformer PST is used to control the active power flow in three phase electricity transmission network. It can increase reliability and can serve as an alternative to new investments in overhead lines. The control of active power flow is achieved by adjusting the phase angle of the voltages at the PST terminals. In this paper, 230 kV AC transmission line is chosen for active power flow control. Two conditions, maximum and minimum load conditions are considered as a case study for active power flow control performance in a selected line. Simulation of active power flow with PST model is carried out by using Matlab software. Finally, according to simulation results, system voltages and active power depend phase angles are revealed in this paper. Thandar Oo | Su Mon Myint | Aye Khaing Zin Änalysis of Active Power Flow Control with Phase Shifting Transformer in AC Transmission Line" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-6 , October 2018, URL: http://www.ijtsrd.com/papers/ijtsrd18593.pdf
@article{noauthororeditor,
abstract = {Nowadays, active power flow should be controlled because voltage fluctuation occurred on various load conditions. Phase shifting transformer PST is used to control the active power flow in three phase electricity transmission network. It can increase reliability and can serve as an alternative to new investments in overhead lines. The control of active power flow is achieved by adjusting the phase angle of the voltages at the PST terminals. In this paper, 230 kV AC transmission line is chosen for active power flow control. Two conditions, maximum and minimum load conditions are considered as a case study for active power flow control performance in a selected line. Simulation of active power flow with PST model is carried out by using Matlab software. Finally, according to simulation results, system voltages and active power depend phase angles are revealed in this paper. Thandar Oo | Su Mon Myint | Aye Khaing Zin "Analysis of Active Power Flow Control with Phase Shifting Transformer in AC Transmission Line" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-6 , October 2018, URL: http://www.ijtsrd.com/papers/ijtsrd18593.pdf
},
added-at = {2018-11-20T10:13:14.000+0100},
author = {Zin, Thandar Oo | Su Mon Myint | Aye Khaing},
biburl = {https://www.bibsonomy.org/bibtex/2450333afcf06c75fca660052c9ba2d19/ijtsrd},
interhash = {e54a5c7925955944d7793a5bc9767a70},
intrahash = {450333afcf06c75fca660052c9ba2d19},
issn = {2456-6470},
journal = {International Journal of Trend in Scientific Research and Development},
keywords = {Electrical Engineering active angle changer control flow line load on phase power shift shifting tap transformer transmission},
language = {English},
month = oct,
number = 6,
pages = {666-672},
timestamp = {2018-11-20T10:13:14.000+0100},
title = {Analysis of Active Power Flow Control with Phase Shifting Transformer in AC Transmission Line
},
url = {http://www.ijtsrd.com/engineering/electrical-engineering/18593/analysis-of-active-power-flow-control-with-phase-shifting-transformer-in-ac-transmission-line/thandar-oo},
volume = 2,
year = 2018
}