The distribution network has many advantages when it is connected to distributed generation (DG). Some
problems in coordination of protection devices will occur in the presence of DG, due to change in short
circuit level at different points. Fault current limiter (FCL) is applying limit to the fault current levels and
the effect of DGs on coordination of overcurrent (O/C) relay during the faults. In distribution network the
use of FCL & DG causes some transient current during fault condition. In such network steady state
coordination method do not result inaccurately. In this method we use fault current limiter for reducing the
transient fault current in the network. The method gives feasible and effective solutions for optimal
coordination in the practical power system networks in comparison to the previous steady state methods
when simulations are carried out on a sample network and the results are demonstrated.
%0 Journal Article
%1 noauthororeditor
%A Chatte, Amit A.
%D 2017
%J Electrical Engineering: An International Journal (EEIJ)
%K (DG), (FCL), Distributed coordination, current distribution fault generation limiter overcurrent, relay system.
%N 1
%P 1-7
%R 10.5121/eeij.2017.4101
%T OVERCURRENT RELAY COORDINATION IN DISTRIBUTED GENERATION WITH FAULT CURRENT LIMITER
%U http://airccse.com/eeij/papers/4117eeij01.pdf
%V 4
%X The distribution network has many advantages when it is connected to distributed generation (DG). Some
problems in coordination of protection devices will occur in the presence of DG, due to change in short
circuit level at different points. Fault current limiter (FCL) is applying limit to the fault current levels and
the effect of DGs on coordination of overcurrent (O/C) relay during the faults. In distribution network the
use of FCL & DG causes some transient current during fault condition. In such network steady state
coordination method do not result inaccurately. In this method we use fault current limiter for reducing the
transient fault current in the network. The method gives feasible and effective solutions for optimal
coordination in the practical power system networks in comparison to the previous steady state methods
when simulations are carried out on a sample network and the results are demonstrated.
@article{noauthororeditor,
abstract = {The distribution network has many advantages when it is connected to distributed generation (DG). Some
problems in coordination of protection devices will occur in the presence of DG, due to change in short
circuit level at different points. Fault current limiter (FCL) is applying limit to the fault current levels and
the effect of DGs on coordination of overcurrent (O/C) relay during the faults. In distribution network the
use of FCL & DG causes some transient current during fault condition. In such network steady state
coordination method do not result inaccurately. In this method we use fault current limiter for reducing the
transient fault current in the network. The method gives feasible and effective solutions for optimal
coordination in the practical power system networks in comparison to the previous steady state methods
when simulations are carried out on a sample network and the results are demonstrated. },
added-at = {2018-02-14T08:24:58.000+0100},
author = {Chatte, Amit A.},
biburl = {https://www.bibsonomy.org/bibtex/281e852ab4cd4b430d65710daa6626ae5/eeijisnowlive},
doi = {10.5121/eeij.2017.4101},
interhash = {5ab10eb856d11b4aeb68c185ac93d9a3},
intrahash = {81e852ab4cd4b430d65710daa6626ae5},
issn = {ISSN : 2349 - 3739},
journal = {Electrical Engineering: An International Journal (EEIJ)},
keywords = {(DG), (FCL), Distributed coordination, current distribution fault generation limiter overcurrent, relay system.},
language = {english},
month = {march},
number = 1,
pages = {1-7},
timestamp = {2018-02-14T08:24:58.000+0100},
title = {OVERCURRENT RELAY COORDINATION IN DISTRIBUTED GENERATION WITH FAULT CURRENT LIMITER},
url = {http://airccse.com/eeij/papers/4117eeij01.pdf},
volume = 4,
year = { 2017}
}