The Monte-Carlo simulated response for γ-ray detection of the FAst TIMing Array (FATIMA) for exploitation within the DEcay SPECtroscopy (DESPEC) experimental system at the FAIR Phase-0 facility at Darmstadt, Germany is presented. In this configuration, FATIMA consisted of 36 LaBr3(Ce) detectors surrounding the AIDA, position-sensitive charged-particle active stopper. The decay of the Iπ=8+ isomer-fed decay cascade in 96Pd, measured in the first DESPEC experiment at the FAIR-0 facility was used to validate the simulations. The experimental data yielded in-situ full-energy peak efficiency values for FATIMA of 11.2(11)%, 6.8(7)%, 3.8(4)% and 2.1(4)% at 106, 325, 684 and 1415 keV respectively, consistent with the values derived from the simulated response.
Description
Response of the FAst TIMing Array (FATIMA) for DESPEC at FAIR Phase-0 - ScienceDirect
%0 Journal Article
%1 CHISHTI2023168597
%A Chishti, M.M.R.
%A Jazrawi, S.
%A Shearman, R.
%A Regan, P.H.
%A Podolyák, Zs.
%A Collins, S.M.
%A Górska, M.
%A Cederwall, B.
%A Yaneva, A.
%A Zhang, G.X.
%A Cederkall, J.
%A Goasduff, A.
%A Albers, H.M.
%A Alhomaidhi, S.
%A Banerjee, A.
%A Bruce, A.M.
%A Benzoni, G.
%A Das, B.
%A Davinson, T.
%A Fraile, L.M.
%A Gerl, J.
%A Häfner, G.
%A Jolie, J.
%A Hubbard, N.
%A John, P.R.
%A Lozeva, R.
%A Mistry, A.K.
%A Singh, B.S. Nara
%A Mikolajczuk, M.
%A Polettini, M.
%A Pietralla, N.
%A Regis, J.M.
%A Rudigier, M.
%A Sahin, E.
%A Sharma, A.
%A Si, M.
%A Vesic, J.
%A Werner, V.
%D 2023
%J Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
%K jolie myown
%P 168597
%R https://doi.org/10.1016/j.nima.2023.168597
%T Response of the FAst TIMing Array (FATIMA) for DESPEC at FAIR Phase-0
%U https://www.sciencedirect.com/science/article/pii/S0168900223005879
%V 1056
%X The Monte-Carlo simulated response for γ-ray detection of the FAst TIMing Array (FATIMA) for exploitation within the DEcay SPECtroscopy (DESPEC) experimental system at the FAIR Phase-0 facility at Darmstadt, Germany is presented. In this configuration, FATIMA consisted of 36 LaBr3(Ce) detectors surrounding the AIDA, position-sensitive charged-particle active stopper. The decay of the Iπ=8+ isomer-fed decay cascade in 96Pd, measured in the first DESPEC experiment at the FAIR-0 facility was used to validate the simulations. The experimental data yielded in-situ full-energy peak efficiency values for FATIMA of 11.2(11)%, 6.8(7)%, 3.8(4)% and 2.1(4)% at 106, 325, 684 and 1415 keV respectively, consistent with the values derived from the simulated response.
@article{CHISHTI2023168597,
abstract = {The Monte-Carlo simulated response for γ-ray detection of the FAst TIMing Array (FATIMA) for exploitation within the DEcay SPECtroscopy (DESPEC) experimental system at the FAIR Phase-0 facility at Darmstadt, Germany is presented. In this configuration, FATIMA consisted of 36 LaBr3(Ce) detectors surrounding the AIDA, position-sensitive charged-particle active stopper. The decay of the Iπ=8+ isomer-fed decay cascade in 96Pd, measured in the first DESPEC experiment at the FAIR-0 facility was used to validate the simulations. The experimental data yielded in-situ full-energy peak efficiency values for FATIMA of 11.2(11)%, 6.8(7)%, 3.8(4)% and 2.1(4)% at 106, 325, 684 and 1415 keV respectively, consistent with the values derived from the simulated response.},
added-at = {2024-01-15T09:56:20.000+0100},
author = {Chishti, M.M.R. and Jazrawi, S. and Shearman, R. and Regan, P.H. and Podolyák, Zs. and Collins, S.M. and Górska, M. and Cederwall, B. and Yaneva, A. and Zhang, G.X. and Cederkall, J. and Goasduff, A. and Albers, H.M. and Alhomaidhi, S. and Banerjee, A. and Bruce, A.M. and Benzoni, G. and Das, B. and Davinson, T. and Fraile, L.M. and Gerl, J. and Häfner, G. and Jolie, J. and Hubbard, N. and John, P.R. and Lozeva, R. and Mistry, A.K. and Singh, B.S. Nara and Mikolajczuk, M. and Polettini, M. and Pietralla, N. and Regis, J.M. and Rudigier, M. and Sahin, E. and Sharma, A. and Si, M. and Vesic, J. and Werner, V.},
biburl = {https://www.bibsonomy.org/bibtex/2e28db5ceeef6ab15e692f6aec9efd243/ikpcologne},
description = {Response of the FAst TIMing Array (FATIMA) for DESPEC at FAIR Phase-0 - ScienceDirect},
doi = {https://doi.org/10.1016/j.nima.2023.168597},
interhash = {625c2eafe91e0fee119ae0abdbd69a5d},
intrahash = {e28db5ceeef6ab15e692f6aec9efd243},
issn = {0168-9002},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
keywords = {jolie myown},
month = {November},
pages = 168597,
timestamp = {2024-01-15T09:56:20.000+0100},
title = {Response of the FAst TIMing Array (FATIMA) for DESPEC at FAIR Phase-0},
url = {https://www.sciencedirect.com/science/article/pii/S0168900223005879},
volume = 1056,
year = 2023
}